Dairy Engineering Full Subject Test

Refrigeration Engineering

Start Practice → अभ्यास शुरू करें →
5 Questions / Batch 5 प्रश्न / बैच
9
Total Questions कुल प्रश्न
2024
1 Paper
Papers Covered कुल पेपर्स
1 Exam Years 1 परीक्षा वर्ष
7.5%
Exam Weightage परीक्षा वेटेज
In 2024 Exam 2024 परीक्षा में
5 Chapters
Syllabus Chapters पाठ्यक्रम अध्याय
4 Question Types 4 प्रश्न प्रकार
Question Types: प्रश्न प्रकार:
MCQ (Single Correct) MCQ (एकल सही) 3 Statement Based कथन आधारित 2 Assertion & Reason अभिकथन एवं कारण 2 Arranging Order क्रम व्यवस्था 2

Previous Years Questions (PYQ) Statistics विगत वर्षों के प्रश्न (PYQ) सांख्यिकी

Year-wise question count, paper frequency, and exam weightage percentage for Refrigeration Engineering: Refrigeration Engineering हेतु वर्षवार प्रश्नों की संख्या, पेपर आवृत्ति और परीक्षा वेटेज प्रतिशत:

Year वर्ष Questions प्रश्न Avg / Paper औसत / पेपर Weightage & Trend वेटेज व ट्रेंड
2024 9 Qs 9.0
7.5% —

All Questions in this Subject इस विषय के सभी प्रश्न

9 Questions 9 प्रश्न
1
Headquarter of WTO is at
Insulation, Barriers & Ice Bank Tanks Insulation, Barriers & Ice Bank Tanks ICAR JRF Dairy Engineering 2024 Shift 1 MCQ (Single Correct) +4 / −1
2

Read the following statements

A. The permeability coefficient increases as the pressure increases
B. Diffusion coefficient increases with an increase in temperature
C. Highly polar polymers are excellent water vapour barriers
D. Non-polar polymers have excellent water barrier properties

Choose the correct answer from the options given below:

Insulation, Barriers & Ice Bank Tanks Insulation, Barriers & Ice Bank Tanks ICAR JRF Dairy Engineering 2024 Shift 1 MCQ (Single Correct) +4 / −1
3

Given below are two statements

Statement (I) : Mozzarella cheese is rennet coagulated cheese
Statement (II) : Acid can be used in Mozzarella cheese for pH reduction

In light of the above statements, choose the most appropriate answer from the options given below.

Multi-Pressure Refrigeration Systems Multi-Pressure Refrigeration Systems ICAR JRF Dairy Engineering 2024 Shift 1 Statement Based +4 / −1
4

The correct sequence of components of a VCRS refrigeration system in the direction of the flow of refrigerant starting with the moving part is

A. Evaporator
B. Condenser
C. Expansion Valve
D. Compressor

Choose the correct answer from the options given below:

Vapour Compression Refrigeration Vapour Compression Refrigeration ICAR JRF Dairy Engineering 2024 Shift 1 Chronological +4 / −1
5

Given below are two statements, one is labelled as Assertion (A) and other one labelled as Reason (R).

Assertion (A) : Subcooling is always desirable to reduce the operating cost of the refrigeration system.
Reason (R) : The sub-cooling of the refrigerant increases the refrigerating effect per kg of refrigerant circulated in the system without any change in the work of compression

In light of the above statements, choose the correct answer from the options given below.

Vapour Compression Refrigeration Vapour Compression Refrigeration ICAR JRF Dairy Engineering 2024 Shift 1 Assertion & Reason +4 / −1
6

Given below are two statements

Statement (I) : Vapour absorption refrigeration systems using water-lithium bromide operate under vacuum,
Statement (II) : Vapour absorption refrigeration systems using water-lithium bromide are used in large air conditioning systems.

In light of the above statements, choose the most appropriate answer from the options given below.

Vapour Absorption Refrigeration Vapour Absorption Refrigeration ICAR JRF Dairy Engineering 2024 Shift 1 Statement Based +4 / −1
7
Which of the following statements can be classified as refrigeration (|) Maintaining a closed space at a temperature of 100 F when surroundings are at a temperature 50 °C (\l) Reducing the temperature of a body from 50 °C to 40 °C when the surrounding temperature is 35 °C. (Ill) Reducing the temperature of a food item in open atmospheric conditions from some initial temperature to 15 °C when the surrounding temperature is 0 °C. (IV) Decreasing the temperature of a room from 37 °C to 20 °C when the outdoor temperature is 40 °C.

Choose the correct answer from the options given below:

Vapour Absorption Refrigeration Vapour Absorption Refrigeration ICAR JRF Dairy Engineering 2024 Shift 1 MCQ (Single Correct) +4 / −1
8
Arrange the following in order of their increasing numerical values A) Effective energy ratio for heating by a heat pump B) COP of simple VCRS C) Overall COP of simple VARS

Choose the correct answer from the options given below:

Refrigeration COP & Operating Params Refrigeration COP & Operating Params ICAR JRF Dairy Engineering 2024 Shift 1 Chronological +4 / −1
9

Given below are two statements, one is labelled as Assertion (A) and other one labelled as Reason (R).

Assertion (A) : Operation of the refrigeration plant at higher condensing temperature/pressure is not desirable
Reason (R) : Higher condensing temperature/pressure adversely affects the COP of the system as refrigerating effect decreases and work of compression increases

In light of the above statements, choose the correct answer from the options given below.

Refrigeration COP & Operating Params Refrigeration COP & Operating Params ICAR JRF Dairy Engineering 2024 Shift 1 Assertion & Reason +4 / −1

Syllabus Chapters Breakdown पाठ्यक्रम अध्याय विभाजन

5 Chapters 5 अध्याय
Official PYQ Papers

Previous Year Papers of Dairy Engineering

Practice official shift-wise question papers with answer keys and detailed explanations on the actual exam pattern.

1
Total Available Previous Papers

Choose Exam

Exam Directory

Browse official Previous papers and mock tests

11 Major Agriculture Exams Available