Highly efficient industrial particulate emission control devices that use high-voltage electrical fields (30–75 kV) to ionize flue gases, electrostatically charge airborne dust particles, and collect them onto oppositely charged collector plates.
Achieves the highest collection efficiency (99.0% to 99.9%) for fine sub-micron particulates compared to cyclonic scrubbers, settling chambers, and dynamic precipitators. (Correct answer: Option 4)
Explanation not matching this question?क्या व्याख्या इस प्रश्न से मेल नहीं खा रही?Report
27
ICAR JRF Environmental Sciences 29 Jun 2024Shift 1
MCQ (Single Correct)+4−1
Which of the following is correct regarding disposal of waste by land filling?
An engineered municipal solid waste disposal technique involving compaction of refuse in thin layers and daily covering with impermeable inert earth/soil.
Properly managed, compacted, and sealed sanitary landfill cells prevent open decomposition odors and foul gas emissions at the surface while being highly cost-effective and economical. (Correct answer: Option 3)
Explanation not matching this question?क्या व्याख्या इस प्रश्न से मेल नहीं खा रही?Report
28
ICAR JRF Environmental Sciences 29 Jun 2024Shift 1
MCQ (Single Correct)+4−1
What is the next step after water abstraction in wastewater treatment?
Water Supply Cycle Steps: Following raw water abstraction (intake from surface reservoirs or groundwater aquifers), the extracted water must immediately undergo Treatment (coagulation, flocculation, sedimentation, filtration, and disinfection) before entering the distribution network.
Empirical Turbidity-TSS Relationship: For well-settled secondary effluents from biological wastewater treatment plants (such as activated sludge processes), Total Suspended Solids (TSS) correlates linearly with turbidity via the standard empirical formula:
Operational Utility: This established ratio enables wastewater plant operators to rapidly estimate suspended solid loadings in real time using continuous turbidity meter readings without waiting for gravimetric oven-drying tests.
Correct option: (1) TSS = (2.3) x Turbidity
Explanation not matching this question?क्या व्याख्या इस प्रश्न से मेल नहीं खा रही?Report
30
ICAR JRF Environmental Sciences 29 Jun 2024Shift 1
MCQ (Single Correct)+4−1
What is the method of treatment used when the TSS in the sample would be high?
High-Rate Solid Contact Clarifier (HRSCC): When wastewater contains high concentrations of Total Suspended Solids (TSS) and turbidity, an HRSCC is employed. It integrates rapid chemical mixing, internal sludge recirculation, flocculation, and high-rate upflow clarification in a single compact unit.
Comparison with Filtration: Media filters (such as pressure sand or granular activated carbon filters) would rapidly blind, clog, and require excessive backwashing if subjected to high TSS influent without preliminary high-rate clarification.
Correct option: (2) High rate solid contact clarifier
Explanation not matching this question?क्या व्याख्या इस प्रश्न से मेल नहीं खा रही?Report
Report Issue / Suggest Correctionत्रुटि रिपोर्ट / संशोधन सुझाव
No official replies published yet for this questionइस प्रश्न पर अभी कोई आधिकारिक समाधान प्रकाशित नहीं है
Have an objection, typo, or doubt? Submit a report in Tab 1. Our subject experts will audit the question and publish the official resolution here.यदि आपको इस प्रश्न या उत्तर कुंजी में कोई आपत्ति है, तो 'त्रुटि रिपोर्ट' टैब से विवरण भेजें। हमारी विषय विशेषज्ञ टीम समीक्षा कर आधिकारिक समाधान प्रकाशित करेगी।