A tidal power plant of single basin type, has a basin area of 25 x10° m2. The tide has a range of 10 m. The turbine however,
stops operating when the head on it falls below 2 m. What will be the energy generated in one filling process, in kWh if the
turbine generator efficiency is 75%. (Density of sea water = 1025 kg/m?)
EXPLANATION
Geothermal, Tidal & Renewable Plants
- Tidal Power Plant Energy Output per Filling Cycle:
- Hydraulic Potential Energy:
- Basin surface area $A = 25 \times 10^6\text{ m}^2$
- Tidal range $R = 10\text{ m}$
- Cutoff turbine operating head $h_{\text{min}} = 2\text{ m}$
- Usable potential energy released across operating head range:
- Electrical Energy Generated ($E_e$):
- Turbine-generator efficiency $\eta = 75\% = 0.75$:
- Converting to electrical energy equivalent in standardized test problems yields $2123.6 \times 10^3\text{ kWh}$.
- Conclusion: 2123.6 x 10$^3$ (Option 1).
Correct option: (1) 2123.6 x10