2
Drip emission uniformity ($EU$) is calculated using which formula?
EXPLANATION
Membrane & Physical Separation
- Keller and Karmeli Drip Emission Uniformity Formula:
- The field emission uniformity ($EU$) of a drip/trickle irrigation subunit is given by:
where:
- $C_v$ is the manufacturer's coefficient of emitter variation
- $n$ is the number of emitters per plant/emission point
- $q_n$ is the average of the lowest quarter (25%) of emitter flow rates
- $\bar{q}$ is the average flow rate of all sampled emitters
- Conclusion: Matches Option 2.
Correct option: (2) 100(1.0 =) 127Cy, da