Calculate the flow rate required for a drip irrigation system to irrigate on orchard of one hectare area with a water depth of 216 mm in 6 hours. The drip system will have 50 cm spacing between emitters on the drip lines, and lateral to latural spacing of 5m. Calculate the discharge of each entities
Choose the correct answer from the options given below:
- Drip Irrigation Discharge Design:
- Total volume required = $10,000\text{ m}^2 \times 0.216\text{ m} = 2,160\text{ m}^3$ in $6\text{ hours} = 360\text{ m}^3/\text{h} = 100\text{ L/s} = 6\text{ m}^3/\text{min}$.
- Emitter spacing = $0.5\text{ m}$, lateral spacing = $5\text{ m} \implies \text{Area per emitter} = 2.5\text{ m}^2$.
- Number of emitters = $\frac{10,000}{2.5} = 4,000$.
- Discharge per emitter = $\frac{360,000\text{ L/h}}{4,000} = 90\text{ L/h}$.
- Conclusion: Statements (A), (B), and (C) only represent valid hydraulic flow rates. (Correct answer: Option 2)