109
ICAR JRF Water Science 29 Jun 2024Shift 1
MCQ (Single Correct) +4 −1

Calculate the flow rate required for a drip irrigation system to irrigate on orchard of one hectare area with a water depth of 216 mm in 6 hours. The drip system will have 50 cm spacing between emitters on the drip lines, and lateral to latural spacing of 5m. Calculate the discharge of each entities

(A) . 100 litisec
(B) . 9 li hour
(C) .6 m/min
(D) . 3.24 lit’ hour

Choose the correct answer from the options given below:

  • Drip Irrigation Discharge Design:
  • Total volume required = $10,000\text{ m}^2 \times 0.216\text{ m} = 2,160\text{ m}^3$ in $6\text{ hours} = 360\text{ m}^3/\text{h} = 100\text{ L/s} = 6\text{ m}^3/\text{min}$.
  • Emitter spacing = $0.5\text{ m}$, lateral spacing = $5\text{ m} \implies \text{Area per emitter} = 2.5\text{ m}^2$.
  • Number of emitters = $\frac{10,000}{2.5} = 4,000$.
  • Discharge per emitter = $\frac{360,000\text{ L/h}}{4,000} = 90\text{ L/h}$.
  • Conclusion: Statements (A), (B), and (C) only represent valid hydraulic flow rates. (Correct answer: Option 2)
Explanation not matching this question? क्या व्याख्या इस प्रश्न से मेल नहीं खा रही? Report
Want to practice this paper in exam conditions? क्या आप परीक्षा जैसे माहौल में अभ्यास करना चाहते हैं? Test yourself in 5-question batch format with timer and hidden answers. 5-प्रश्नों के बैच फॉर्मैट, टाइमर और छिपे उत्तरों के साथ खुद को परखें।
Start Practice Mode → प्रैक्टिस टेस्ट मोड शुरू करें →

Water Science and Technology विषय एवं अध्याय

विषय एवं पाठ्यक्रम के अनुसार सभी अध्याय देखें

Official PYQ Papers

Previous Year Papers of Water Science and Technology

Practice official shift-wise question papers with answer keys and detailed explanations on the actual exam pattern.

1
Total Available Previous Papers

Choose Exam

Exam Directory

Browse official Previous papers and mock tests

10 Major Agriculture Exams Available