Hydrometer readings are corrected for :
Choose the correct answer from the options given below :
मृदा कण आकार विश्लेषण में हाइड्रोमीटर पाठ्यांक (Hydrometer readings) को किसके लिए संशोधित किया जाता है?
नीचे दिए गए विकल्पों में से सही उत्तर चुनिए :
Detailed Analysis of Hydrometer Analysis Corrections:
In grain-size analysis of fine-grained soils (sedimentation by hydrometer method), the observed hydrometer reading ($R_h$) requires three essential corrections:
- Meniscus Correction ($C_m$): Always positive (+), because opaque soil suspensions necessitate reading the top of the meniscus rather than the liquid level.
- Temperature Correction ($C_t$): Can be positive (+) or negative (-) depending on whether test temperature is above or below calibration temperature ($27^\circ\text{C}$).
- Dispersing Agent Correction ($C_d$): Always negative (-), because the added deflocculating chemical increases liquid specific gravity.
$$R = R_h + C_m \pm C_t - C_d$$ - Pressure correction is not applied in hydrometer analysis.
हाइड्रोमीटर विश्लेषण संशोधनों का विस्तृत विश्लेषण:
मृदा यांत्रिकी में महीन कणों के अवसादन विश्लेषण (Stokes' Law) हेतु हाइड्रोमीटर पाठ्यांक ($R_h$) में तीन प्रमुख संशोधन किए जाते हैं:
- नवचंद्रक संशोधन ($C_m$): अपारदर्शी मृदा घोल में पाठ्यांक नवचंद्रक के ऊपरी सिरे पर लिया जाता है, अतः यह सदैव धनात्मक (+) होता है।
- तापमान संशोधन ($C_t$): यदि तापमान मानक अंशांकन तापमान ($27^\circ\text{C}$) से भिन्न हो, तो यह धनात्मक या ऋणात्मक होता है।
- परिक्षेपण कारक संशोधन ($C_d$): परिक्षेपक (जैसे सोडियम हेक्सामेटाफॉस्फेट) मिलाने से घोल का घनत्व बढ़ता है, अतः यह सदैव ऋणात्मक (-) होता है।
- दाब संशोधन का हाइड्रोमीटर में कोई संबंध नहीं होता।